Pumps


Since 1924 Japanese pump manufacturer Tsurumi Pump has been producing pumps that satisfy customer’s demands for high quality, safety, and reliability.

Featuring:

  • Main components are made with 304 stainless-steel abd composite resin 
  • Ultra-lightweight
  • Watertight Cable Entrance with Anti-wicking block.
  • Permanently lubricated sealed ball bearings rated B-10 60,000 hours.
  • Built in motor protection
  • Continuous duty air filled copper wound highly efficient motor.
  • Corrosion Resistant Stainless Steel Motor Casing.
  • Dual inside mechanical with Silicon Carbide vs. Ceramic bottom faces.
  • Solids handling semi-vortex impeller

 

Model Flow rate in gallons per hour
@0′  @ 5′ @10′ @15″ @20′
2OM 2640  2400 2000 1500 960
3PN 4000 4000 3200 2600 1800
4PN 4900 4900 4400 3800 3100
8PN 6000 6000 5700 5200 4800
12PN  11,500 10,000 7500 4500 1500
@5′ @7′ @8′ @9′ @10′ @11′ @12′
4H (115V)
(4″ pipe required)
10,000 8,000 7,000 4,000
15H (230V)
(6″ pipe required)
(Inverter Panel
required)
30,000 24,000 22,000 18,000 15,000 11,000 8,000
Inverter Panel for three-phase (220V) pumps Tsurumi Water Feature Inverter Panels allow a three-phase/220V pump to operate on a single-phase/220V power supply.
The inverter panel incorporates a variable speed controller to allow home owners greater control of the flow and feel of thier water feature.
Efficiency: Three-phase motors are more efficient that single phase motors (often higher than 30%)Reliability: Three-phase motors are more reliable than single phase motors
(frequently lasting 10 times longer)
Cost Saving: Three-phase motors are generally less expensive to operate than single-phase motorsFeatrures & Advantages:

  • Protects the pump from voltage overload and power loss.
  • Prevents short circuits from damaging the pump motor.
  • Extends the life of the pump through the use of”soft-start”.
  • Allows the pump to operate at slower speeds for critical water circulation.
  • Replaces the need for multiple speed motors.
  • Home owner has greater control of flow for aesthetics and noise effect.
  • Large commercial pumps can operate using residential power sources producing increased flow rates.

 

 

Heavy duty pond cleanout pumps for quickly emptying a pond for service.
They can run continously at low water levels making them ideal for start ups and clean ups.
Pump and collapsable pipe combo packages available.

Model Discharge HP Cable
Length
Max Solid
Diam. (in.)
Continuous
Running Water
Level (in.)
Voltage
HS2.4S
(with residue kit)
2″ 1/2 20 1/4 1/2″
(with residue kit)
115
LRR2.4S 2″ 2/3 32 1/5 1/4″ 115
Triton Check Valve The Triton Check Valve is the only check valve designed exclusively for the water garden industry.

The ‘swing style’ Triton Checkvalve features a 2″ socket union on the inlet, 2″ and 1.5″ socket unions for the outlet, a moulded-in 90 degree elbow, and a slim design that allows clearance when installed with direct drive pumps.

If simplicity and innovation is what you seek, Triton delivers.

 

Pentair Diaphram Pump Switch 
Converts any manual pump, up through 1 HP (10 max. run amps), to automatic. Can be mounted to your pump 8″ below the water line level you which to have the pump cease operation.  This pump switch will add reassuring protection for your pump.
New!! OASE – Waterfall Pump

  • Energy efficient motor, saves power and money in operation
  • High cleaning force, it pumps pond water and coarse debris particles, up to 1/2 inch through the mechanical filter

Screen Shot 2017-07-21 at 11.28.46 AM
Oase-Waterfall-Pump-6600-300x300

 

New!! OASE – AquaMax Eco Classic Pond Pump

  • Moves debris from the pond bottom to the pond filter, helping to maintain the ecosystem’s health, natural balance, and beauty
  • Pumps pond water and coarse debris particles up to 3/9″ in size
  • Environmental Function Control (EFC) shuts off the pump in the event of a dry run or blockage to stop the pump from damaging itself
    Screen Shot 2017-06-12 at 3.48.26 PM oase aqua max pump

Hayward In-Line Super Pumps

Hayward’s SuperPump series of technology advanced large-capacity pumps

delivers cost-effective, sturdy construction, while setting an industry standard for value and excellence.

Built for water features of all sizes and types, each unit contains a super-sized debris basket, large see-through strainer, and exclusive easy-to-service design for added convience.

The heavy-duty high-performance motor includes airflow ventilation for cooler, quieter operation.

The see-though strainer cover allows you to see when the basket requires cleaning. Exclusive swing-away handle makes it easy to remove the strainer cover – no tools, no clamps, and no loose parts.  110-cubic inch basket

Pump GPH
@0′
GPH
@5′
GPH
@10′
GPH
@15′
GPH
@20′
GPH
@30′
Discharge HP AMPS
120V/240V
Voltage
X5 360 270 205 80 1 1/2″ 1/2 3.1 / 1.5 115/230
X7 480 405 335 270 170 1 1/2″ 3/4 4.7 / 2.3 115/230
X10 570 480 425 325 205 1 1/2″ 1 6.2 / 3.1 115/230
X15 640 530 460 390 290 90 1 1/2″ 1.5 9.3 / 4.6 115/230
X20 975 780 740 685 610 450 2″ 2 12.4 / 6.2 230V

EcoStar variable speed pump

EcoStar variable speed pump-the most efficient pool pump available at any speed. This pool pump can save up to 90% on your energy costs compared with ordinary single-speed unit. Instead of running continuously at maximum power, the EcoStar pump efficiently regulates its flow according to the water features requirements at any given time. It is suitable for new construction as well as the aftermarket.

  • The most efficient pump on the market. Its permanent super-efficient magnet, completely enclosed fan-cooled (TEFC) motor, and industry-best hydraulic construction can save as much as 90% on energy costs.
  • The programmable integrated controller features a self-contained 24-hour clock and as many as eight custom timer and speed functions that enable the pump to regulate flow efficiently and continuously.
  • The service mode permits a service company to clean the pool safely and more quickly.
  • The user interface can change position or even be removed and remounted on a wall for easy access.
Pump Output (GPM) vs. Total Resistance to Flow
(Feet of Head)
RPM % Output’ 10′ 20′ 30′ 40′ 50′ 60′ 70′ 80′
1375 40 51
1725 50 78 45
2075 60 100 82 41
2425 70 117 110 90 56
2750 80 113 133 118 100 73
3100 90 149 149 144 130 117 91 36
3450 100 166 166 166 158 144 130 111 85